Construction tolerances
The components used to construct buildings are often fabricated, assembled or formed on site, often by hand, in conditions that may be less than ideal, and using materials with inherent ‘imperfections’. Whilst it is easy to draw a straight line on a drawing, to give an precise dimension, an exact mix or position it is impossible to construct, for example, concrete that is perfectly straight, simply by virtue of the inherent properties of the material itself.
It can be difficult therefore to determine whether a variation from perfection is simply a function of the nature of a particular type of construction or material, or whether it constitutes a defect. For this reason it is important to specify allowable variations, or ‘tolerances’, that are not considered to be defects.
The concept of tolerances is also be important when assembling a number of components, as some items may have very little flexibility to accommodate variations in neighbouring items. For example, it may be relatively straight forward to adjust the setting out of brickwork to accommodate a slight variation in the size of a timber beam, or simply to cut the beam on site, but if a double glazing unit is even a millimetre larger than the opening for which it is intended, it simply will not fit. Even when individual items appear to be reasonably close to what was specified, variations can accumulate when a number of components are assembled, and this can create a clash with an item that may have a low tolerance.
This is becoming more important as the number of items prefabricated off site has increased, and so there is less scope for changes on site to make things fit.
In addition to dimensions, tolerances may be used to specify allowable variations in strength, stability, the mix of a material, the performance of a system, temperature ranges and so on.
There are a thousands of different standards available setting out accepted classes and ranges of tolerance for different materials, components, systems, construction techniques, fabrication methods, installation techniques and building types. These may range from relatively large tolerances for site layouts or landscaping to very precise tolerances for manufactured components.
It is important that tolerances are clearly specified in contract documents and that they are properly understood by designers, fabricators, contractors and site supervisors.
NB Government Functional Standard, GovS 002: Project delivery; portfolio, programme and project management, Version: 2.0, published on 15 July 2021 by HM Government, defines tolerance as: ‘The permissible deviation above and below a plan’s target for time and cost without escalating the deviation to the next level of management. There can also be tolerance levels for quality, scope, benefit and risk. Tolerance is applied at project, stage and team levels.’
The BSRIA guide to 'Commissioning Air Systems' (BG 49/2024), written by by Keith Barker and published by BSRIA in March 2024, explains how to commission ducted air distribution systems in buildings. It was originally published in 2013, then 2015 with the latest update in 2024. It defines tolerance as: 'The permissible range of variation from the specified design value.'
[edit] Related articles on Designing Buildings
- Accuracy.
- Buildability.
- Building information modelling.
- Clash avoidance.
- Construction quality.
- Defects.
- Design coordination.
- Offsite manufacturing.
- Prefabrication.
- Precision.
- Quality control.
- Samples and mock-ups.
- Site inspection.
- Site inspector.
- Spacing.
- Specification.
- Testing construction materials.
- Types of drawing.
Featured articles and news
Boiler Upgrade Scheme and certifications consultation
Summary of government consultation which closes 11 June 2025.
Deputy editor of AT, Tim Fraser, discusses the newly formed society with its current chair, Chris Halligan MCIAT.
Barratt Lo-E passivhaus standard homes planned enmasse
With an initial 728 Lo-E homes across two sites and many more planned for the future.
Government urged to uphold Warm Homes commitment
ECA and industry bodies write to Government concerning its 13.2 billion Warm Homes manifesto commitment.
Places of Worship in Britain and Ireland, 1929-1990. Book review.
The emancipation of women in art.
CIOB Construction Manager of the Year 2025
Just one of the winners at the CIOB Awards 2025.
Call for independent National Grenfell oversight mechanism
MHCLG share findings of Building Safety Inquiry in letter to Secretary of State and Minister for Building Safety.
The Architectural Technology Awards
AT Awards now open for this the sixth decade of CIAT.
50th Golden anniversary ECA Edmundson awards
Deadline for submissions Friday 30 May 2025.
The benefits of precast, off-site foundation systems
Top ten benefits of this notable innovation.
Encouraging individuals to take action saving water at home, work, and in their communities.
Takes a community to support mental health and wellbeing
The why of becoming a Mental Health Instructor explained.
Mental health awareness week 13-18 May
The theme is communities, they can provide a sense of belonging, safety, support in hard times, and a sense purpose.
Mental health support on the rise but workers still struggling
CIOB Understanding Mental Health in the Built Environment 2025 shows.
Design and construction material libraries
Material, sample, product or detail libraries a key component of any architectural design practice.
Construction Products Reform Green Paper and Consultation
Still time to respond as consultation closes on 21 May 2025.
Resilient façade systems for smog reduction in Shanghai
A technical approach using computer simulation and analysis of solar radiation, wind patterns, and ventilation.